New Wireless Interconnected Battery Powered Smoke & Heat Alarms Pre Linked Kit

New Wireless Interconnected Battery Powered Smoke & Heat Alarms Pre Linked Kit

New Wireless Interconnected Battery Powered Smoke & Heat Alarms Pre Linked Kit

Sport Golf Pride Grips Align MCC Plus 4 Multi Compound Standard Midsize 3 Colors. 1-13Pcs Golf Pride Club Grips MCC PLUS 4 Multi Compound Grip Standard/Midsize. Wireless Interconnected 3 Smoke Alarm + 1 Heat Detector+1 Remote Pre Linked Kit. New RF Wireless Interconnected Smoke & Heat Detector Alarm Kit (1 Heat, 3 Smoke).

Wireless Interconnected 4Smoke Alarm & 1Heat Detector With Remote Pre Linked Kit. Wireless Interconnected 2 Smoke Alarm & 1 Heat Detector Starter Pre Linked Kit. New Wireless Interlinked RF Photoelectric Smoke Alarm Heat Alarm 10 Year Battery.

New Wireless Interconnected 4Smoke Alarm & 1Heat Detector With 10 Year Battery. One goes all go interconnected. So that they all sound when one is activated, warning you of fire throughout your home and increasing safety, keeping you and your family safe. Interconnected / Interlinked / connected / Linked system Suitable for multiple places. Fully compliant with the new Scottish law meeting standards EN14604 and BS5446 Heat Detectors - Ideal for the Kitchen - BS5446 Compliant Smoke Detectors - For use in any other room excluding the bathroom - EN14604 Compliant Smoke alarms should be installed in every room (except the bathroom and kitchen), finished attics and basements, making sure the people in your home will be able to hear and respond to the alarm sound.

Heat detectors should be fitted in your Kitchen so that smoke from accidentally burning something whilst cooking doesn't set off the alarm. Smoke and Heat detectors are an essential part of your home or apartment. Their loud, piercing alarms should wake you if there's a problem, so you and your loved ones can safely escape, or put out the fire. Store it in a safe place for future reference. Power: DC 3V Battery Package: CR145052 Lithium Battery(sealed in) Operation Current.

85 dB(A) at 3 meters Alarm Sensitivity: 0.09 - 0.17 dB/m Low Battery: 2.6 ± 0.1 V Frequency : 433.92MHz Silence Time: approx. 10 minutes Working distance : Up to 100m (Outdoor open) Interlinked devices: : Max 30pcs per group Source/Master smoke alarm sound pattern: BI 0.5s - pause 0.5s - BI 0.5s - pause 0.5s - BI 0.5s - pause 1.5s, with the red LED flash, repeat this alarm pattern. Slave smoke alarm sound pattern: BI 0.1s - pause 0.1s with the red LED flash and sound, repeat this alarm pattern. Comply to Standard EN14604:2005/AC:2008. 1 × Photoelectric smoke alarm.

Install an alarm in the bedroom and. Install an alarm in every bedroom. Smoke, heat and burning things will spread horizontally after rising to the ceiling, so install the alarm. N middle of the ceilin.

Be installed in the middle of the ceiling. If the length of the room or the hall is beyond 30 foot, you need. When the wall or ceiling is slanting, the alarm needs to be installed minimum 500mm away from the highest wall or ceiling point in the room see the.

High-humidity areas such as kitchens, and bathrooms. Next to air outlets, fans and central heating. Dusty, dirty areas or areas with insects.

High-temperature and easily polluted places. Places with difficult access, making it difficult to operate the test function. Within 1.5m from lamps.

Next to doors or windows. In the top of rooms with sloping roofs, the corner of the room or other dead-air spaces. The bracket on the installation position.

On the ceiling or the wall. Drill two mounting holes in the marked place by an electric drill (The diameter of the drill hole is 5mm) and insert two plastic anchor plugs by hammer. Mounting bracket to the ceiling or the wall. Ttach the alarm to the mounting bracket and turn clockwise to lock the alarm.

WARNING: The installation instructions must be followed strictly in case of any injury. How to Power up & off the device.

The device is turned off by default before leaving the factory, Before the device can be used normally, the product must be activated. Press the test button over 10 seconds, when the red LED indicator lighted up, release the test button, the alarm be power up and can be work normally. If you went to power up the device, Press the test button over 10 seconds, when the red LED indicator blinked twice, release the test button, the alarm be power off, and Work suspended. Test the unit to ensure proper operation by pressing the.

If no sounds, you can refer to "Trouble shooting" section for solution. DO NOT test your alarm using an open flame. This may damage the smoke alarm, or ignite combustible materials and start a structural fire.

DO NOT stand close to the alarm when the alarm is sounding. Xposure at close range may be harmful to your. So step away when testing.

Weekly Test: test this smoke alarm once a week. Test status: Red LED flashes once every second. Hush/Silence mode: Red LED flashes once every 8 seconds. Low Battery status: Red LED flashes once every 60 seconds and 1 beep every 60 seconds.

Fault status: the alarm will deliver beeps every 40 seconds. During the unit is alarming, you.

Push the test button, it will be paused the unit alarming for approx 10 minutes. The red LED will flash once every. Seconds, it indicates the smoke alarm device is running into the silence mode. The silence feature is to be used only when a known alarm condition, such as smoke from cooking activates the alarm. The smoke alarm device will automatically reset after approximately 10 minutes, if after this period, particles of combustion are still present, the alarm will sound again. Before using the alarm silence (silence), identify the source of the smoke and be certain a safe condition exists. Radio-interlinked smoke detectors are interlinked through radio-frequency. Larm detects fire, all alarms go off.

In the case of the battery operated radio-interlinked smoke alarms, no wiring is required at all. How to create the interlinked network. Using alarm devices to create network.

Step 1: Press the test/silence. Button on one of these smoke. Alarms 4 times, and the green LED will.

Flash continuously, indicating it has entered the transmitting mode valid time. Step 2: Press the test/silence.

Button on the other smoke alarms twice, and the green LED will. Flash continuously, indicating it has entered the receiving mode. If pairing is successful: The green. LED of these alarms will stop flashing. When it is failure: The green light will continue to flash for 60 seconds, and then the red light will stay on for 2 seconds. Using Remoter to create network. Step 2: Press the Matching button . It has entered the transmitting mode valid time. When the alarm received the signals, the network would be created. How to test the network. When the networking is successful, you can test whether the network is working properly: select any alarm in the network, press the test button, the alarm will start to alarm, and other alarms in the network will also enter the alarm mode; in addition, you can also use the remoter to test, press the Test/Silence button on the remoter, all the alarms in the network will enter the alarm mode. If there are some alarms without alarming in the test, re-join the network according to the instructions in the previous step. How to silence the alarms in network when alarm. The device will goes into Source/Master smoke alarm sound pattern alarmed, and emits the alarm signal; When other alarm devices received alarm signal, they will goes into Slave smoke alarm sound pattern, until the Source/Master alarm device stopped alarm; During the unit is alarming, you can find out the Source/Master. How to disabling the interconnect function. Press the test/silence button on the smoke alarms twice and the green LED will. Then ignore it and it will automatic.

There are a few simple steps you need do to keep it working properly. T the alarm once a week. O not paint the alarm. Paint will seal the vents and interfere with the sensor's ability to detect smoke.

Never attempt to disassemble the alarm to clean inside. Clean the alarm at least once a month to remove dust, dirt, or debris. Use a vacuum cleaner with the soft brush, vacuum all sides and covers of smoke alarm device. The alarm does not sound when testing. Red LED flashes and the alarm delivers one beep every 60.

The batteries as soon as possible. The alarm delivers one beep every 40 seconds. Contact the retailer to replace it. Nuisance alarms triggered intermittently or when residents are cooking. Please refer to the "maintenance and cleaning" section.

Move the alarm to new. Thank you for purchasing our wireless interlinked heat alarm device. This device can convert as single smoke alarm or heat alarm to use. Please read this manual carefully to ensure proper use and store it in a safe place for future reference.

Power: DC 3V Lithium battery. Alarm Volume: >85 dB(A) at 3 meters. Frequency : 433.92MHz or 868MHz. Working distance : Up to 100m (Outdoor open). Interlinked devices: : Max 30pcs per group. Source/Master heat alarm sound pattern: BI 0.5s - pause 0.5s - BI 0.5s - pause 0.5s - BI 0.5s - pause 1.5s, with the red LED flash, repeat this alarm pattern. Slave heat alarm sound pattern: BI 0.1s - pause 0.1s with the red LED flash and sound, repeat this alarm pattern. Comply to Standard BS 5446-2:2003. 1 × Adhere double-side sticker.

At first you should install an alarm in the bedroom and walkway. If there are several bedrooms in the house, please install an alarm in every bedroom. Install an alarm above the stairway and on every floor of the house. Smoke, heat and burning things will spread horizontally after rising to the ceiling, so install the alarm in middle of the ceiling.

If the alarm can not be installed in the middle of the ceiling, install it keeping 300mm away from the corners. If the alarm is installed in the wall, it should keep 100mm away from the ceiling. If the length of the room or the hall is beyond 30 foot, you need to install several alarms there. When the wall or ceiling is slanting, the alarm needs to be installed minimum 500mm away from the highest wall or ceiling point in the room (see the figure 2). Twist off the mounting bracket from the alarm.

Put the bracket on the installation position and mark the screw holes on the ceiling or the wall. Screw the mounting bracket to the ceiling or the wall (Refer to figure 3). Attach the alarm to the mounting bracket and turn clockwise to lock the alarm. Test the unit to ensure proper operation by pressing the cover, the alarm will sound if the unit are working well. Exposure at close range may be harmful to your earning, so step away when testing.

Normal status: Red LED Flashes once every 60 seconds. During the unit is alarming, you can push the test button, it will be paused the unit alarming for approx 10 minutes.

The red LED will flash once every 8 seconds, it indicates the smoke alarm device is running into the silence mode. Radio-interlinked heat alarm are interlinked through radio-frequency signals. If one alarm detects fire, all alarms go off.

In the case of the battery operated radio-interlinked alarms, no wiring is required at all. How to create the interlinked network Methods. 1: Using alarm devices to create network. Step 1: Press the test/silence button on one of these alarms 4 times, and the green LED will rapidly flash continuously, indicating it has entered the transmitting mode (valid time: 60 seconds).

Step 2: Press the test/silence button on the other alarms twice, and the green LED will slowly flash continuously, indicating it has entered the receiving mode. If pairing is successful: The green LED of these alarms will stop flashing.

Press the test/silence button on the smoke alarms twice and the green LED will slowly flash continuously still 60 seconds, then ignore it and it will automatic despairing. Methods 2: Using Remoter to create network. Step 1: Press the test/silence button on the other alarms twice, and the green LED will slowly flash continuously, indicating it has entered the receiving mode. 2: Press the Matching button on the remoter, and the red LED will lighted up, and it has entered the transmitting mode (valid time: 10 seconds). If the alarm detects fire, the device will goes into Source/Master alarm sound pattern alarmed, and emits the alarm signal; When other alarm devices received alarm signal, they will goes into Slave smoke alarm sound pattern, until the Source/Master alarm device stopped alarm.

During the unit is alarming, you can find out the Source/Master alarm, press the Test/Silence button to pause all other interconnected alarms. Test the alarm once a week. Do not paint the alarm. This will damage the alarm. For the model which used lithium battery (included).

The battery service life over 10 years, no need to replace the battery. The battery is sealed in cover and not replaceable, DO NOT TRY TO REPLACE THE BATTERY. We will reply you within 24 hour. All our pictures are real product images. The chromatism caused by monitor is not include the quality problem. We offer 60 days return. We do our best to process as quickly as possible.

All emails will be responded to within 24 hours. This item is in the category "Home, Furniture & DIY\Home Security\Smoke & Gas Detectors". The seller is "jasohungnes04" and is located in this country: CN.

This item can be shipped to United Kingdom.


New Wireless Interconnected Battery Powered Smoke & Heat Alarms Pre Linked Kit


Index   Sitemap   Contact Us   Privacy Policy Agreement   Terms of service